Target
Heat or cool a highly viscous, nonnewtonian and temperature-sensitive product in a rapid and gentle way in order to avoid any damage to the product.
A static mixer causes a continuous rearrangement of the product flow. Boundary layers close to the wall are renewed efficiently and heat transfer is significantly enhanced. Therefore the residence time in the heat exchanger can be reduced and small temperature gradients can be applied. Local overheating is prevented.
Temperature distribution in a Sulzer SMXL™ mixer calculated by CFD method.



back